R501

Advanced Multi-Asset Monitor

Versatile Comprehensive Condition Monitor for Predictive Diagnostics 

Our rack-mount multi-channel edge device offers an all-in-one solution, capable of monitoring a wide range of parameters such as essential asset health, fiber optic temperature, PD, bushing, OLTC, load, power, and more, suitable for diverse industries with extensive electrical infrastructure.

Features
  • Expandable and Field Upgradable
  • Secure Web-Based Interface
  • User-Friendly Design
  • Advanced Health Analytics
  • Comprehensive Connectivity Options 
Benefits
  • Improved Asset Reliability
  • Accurate Predictive Analysis
  • Remote Data Access
  • Single Versatile Solution for Multiple Assets
  • Extended Asset Lifetime
  • Maximum ROI
  • Field-Upgradable Without Downtime 
Applications
  • Transformer Monitoring (Oil Filled/ Dry Type)
  • Switchgear Monitoring (GIS/ AIS/ MV Panel)
  • Cable Monitoring (EHV/ HV/ MV)
  • Motors/ Generators Monitoring (DOL/ VFD) 
Technical specifications

Power Supply

Input Power Requirement

24 – 48 V DC (Default), 120 W, and any other (upon request)

Analog Input Module

# of Input Channels

05 or 10 Channels

AC Current Input

Clamp-on CT with different ranges: 5Amp, 10Amp, 20Amp,
100Amp and others available

DC Current Input

4 – 20 mA

Temperature Input

100 ohm platinum (Pt100)

Potentiometer

up to 20,000 ohms

Analog Output Module

# of Input Channels

08 or 16 Channels

Output format

4-20 mA or 0-5V or 0-10V
Configurable for any measured / calculated value

Digital Input Module
# of Input Channels

08 or 16 Channels

Dry Contact

Resistance between the contact < 100 Ω

Powered Contact

75 – 250Vdc

Output Relay Module
# of Output Channels

04 or 08 Form C relays

Bushing Monitoring Module
# of Input Channels

03 or 06 Channels

Leakage Current Range

1mA to 200mA

Monitoring Parameters

Tan Delta (PF), Capacitance, Phase Voltage

System Capacity

Maximum number of Channels

Expandable to 256 Channels, Daisy chain up to 32 units (with Modbus, Canbus)

Environmental & Mechanical
Operating Temperature

-40°C to 72 °C

Operating Humidity

95% Non Condensing

Storage Temperature

-40°C to 85 °C

Dimensions 8 Chaise

W48.25 x H15.71 x D17.73 cm (19.00″ x 2.25″ x 6.98″)

Weight

App. 5Kg. (for complete filled Chassis)

Partial Discharge Module
# of Input Channels

04 or 08 Channels

Acquisition Bandwidth

HPM: 0.01 – 100Mhz
UPM: 100 MHz – 2 GHz

Monitoring Parameters

PD Amplitude, Discharge Rate and PRPD

EMC Compliance
Conducted & Radiated Emissions

ICES-003 (2016), CISPR32 (2015), CISPR11 (2015)

ESD and EM Field Immunity

IEC61000-4-2, C37.90-3, IEC61000-4-3, C37.90.2

Fast Transient & Surge Immunity

IEC61000-4-4, IEC61000-4-5, C37.90.2

Magnetic Field Immunity

IEC61000-4-8, IEC61000-4-10

Immunity from Conducted Disturbances

IEC61000-4-6, IEC61000-4-16

Ripple, Dips & Damped Oscillatory

IEC61000-4-17, IEC61000-4-18, IEC61000-4-29

Safety

IEC60255-26 and CE Certified

CPU Module
Data Storage Capacity

MicroSD external memory slot (up to 2 TB)

Logging Rate

1 sec interval on USB

Config port

USB (to use with Rugged connect windows software)

Fiber Optic Modules
# of Channels

2, 4, 6 and 8 channels

Measurement Range

-80 °C to +300 °C (cryogenic 4 °K range optional)

Resolution

0.1 °C

Accuracy

±1.0 °C (±0.2 °C in relative temperature)

Scan Rate

200 ms / channel ( Optional: Faster scanning rates available)

Communication Options
Ethernet Ports (RJ-45 & FO Ethernet)

Modbus, DNP3.0, IEC 60870-5-104, MQTT, IEC61850, PRP

Serial Port

RS485 with Modbus support

CANBUS Port

CANBUS Master/Slave support for Can Dataloggers

Power Monitoring Module
# of Input Channels

03 Current and 03 Voltage

Current Input Range

0 – 5A

Voltage Input Range

0 – 250V

Sampling Rate

32 KS/s

Measurement Parameters

Power, Through-Fault, Motor Torque etc.

Product Drawaing

Our Presence Across the Globe

Head Office

CANADA
1415 Frank-Carrel, Suite
230, Quebec, QC – G1N
4N7, CANADA