R501

R501

Rugged, Most Versatile and Multi-Channel monitoring solution, Capable of Monitoring One or Multiple Assets: Basic Asset Monitoring, Fiber Optic Temperature Monitoring, Partial Discharge, Bushing, OLTC, Load, Power, and more.

KEY FEATURES

  • Improved asset reliability
  • Accurate predictive analysis
  • Access asset data from anywhere
  • One monitoring solution for multiple assets
  • Increased asset lifetime

R501 – Rugged fiber optic temperature monitor with plug and play features for increased accuracy and resolution 

R501 is the most advanced monitoring solution designed to monitor multiple electrical assets with its simple and user-friendly interface. R501 provides condition monitoring of electrical assets by focusing on preventing asset failures and downtime. With our comprehensive electrical asset condition monitoring solution, the health of assets can be determined and also maintenance activities can be scheduled.

The system along with sensors, monitors, and software (RMEYE) is completely modular and customizable, with its rack mount design various monitoring can be added as per the requirements and specifications. The solution can be used for existing (retrofit applications) or new electrical assets.

  • Transformer Monitoring (Oil Filled/ Dry Type)
  • Cable Monitoring (EHV/ HV/ MV)
  • Switchgear Monitoring (GIS/ AIS/ MV Panel)
  • Motors/ Generators Monitoring (DOL/ VFD)
  • Highest return on investment
  • Field upgradable with no device downtime
  • Improved asset reliability
  • Accurate predictive analysis
  • Access asset data from anywhere
  • One monitoring solution for multiple assets
  • Increased asset lifetime
TECHNICAL SPECIFICATIONS
POWER SUPPLY
Input Power Requirement
24 - 48 V DC (Default), 120 W, and any other (upon request)
CPU MODULE
Data Storage Capacity
MicroSD external memory slot (up to 2 TB)
Logging Rate
1 sec interval on USB
Config port
USB (to use with Rugged connect windows software)
SYSTEM CAPACITY
Maximum number of Channels
Expandable to 256 Channels, Daisy chain up to 32 units (with Modbus, Canbus)
FIBER OPTIC MODULES
# of Channels
2, 4, 6 and 8 channels
Measurement Range
-80 °C to +300 °C (cryogenic 4 °K range optional)
Resolution
0.1 °C
Accuracy
±1.0 °C (±0.2 °C in relative temperature)
Scan Rate
200 ms / channel ( Optional: Faster scanning rates available)
ANALOG INPUT MODULE
# of Input Channels
05 or 10 Channels
AC Current Input
Clamp-on CT with dierent ranges: 5Amp, 10Amp, 20Amp, 100Amp and others available
DC Current Input
4 - 20 mA
Temperature Input
100 ohm platinum (Pt100)
Potentiometer
up to 20,000 ohms
DIGITAL INPUT MODULE
# of Input Channels
08 or 16 Channels
Dry Contact
Resistance between the contact < 100 Ω
Powered Contact
75 - 250Vdc
ANALOG OUTPUT MODULE
# of Input Channels
08 or 16 Channels
Output format
4-20 mA or 0-5V or 0-10V Configurable for any measured / calculated value
RELAY OUTPUT MODULE
# of Output Channels
04 or 08 Form C relays
COMMUNICATION OPTIONS
Ethernet Ports (RJ-45 & FO Ethernet)
Modbus, DNP3.0, IEC 60870-5-104, MQTT, IEC61850, PRP
Serial Port
RS485 with Modbus support
CANBUS Port
CANBUS Master/Slave support for Can Dataloggers
ENVIRONMENTAL AND MECHANICAL
Operating Temperature
-40 to 72 °C
Operating Humidity
95% Non Condensing
Storage Temperature
-40 to 85 °C
Dimensions
W26.7 cm x H7.2 cm x D18.7 cm (10.5’’ x 2.8” x 7.4”)
Weight
App. 5Kg. (for complete filled Chassis)

BROCHURE

Documents sorted by newest first

CONTACT YOUR LOCAL SALES REPRESENTATIVE