Home > Monitors > O201

O201

Rugged fibre optic temperature monitor with plug and play features for increased accuracy and resolution.

O201 is a compact design, designed for reliability to operate in extreme EMI, RFI, Microwave and high voltage environments. O201 is precisely designed to monitor wide range of electrical asset types and to provide a greater visibility into the assets. O201 combines reliability and user-friendly configuration software. It is a multi-channel fiber optic temperature monitor with precision measurement for original equipment manufacturers.

KEY FEATURES

O201 – Rugged fibre optic temperature monitor with plug and play features for increased accuracy and resolutionThe O201 has a measuring range from -80 °C to +300 °C.  The solution can be used for existing (retrofit applications) or new electrical assets. O201 is designed to collect data and easy to integrate into existing systems through serial communication like RS-485 or analog outputs like 0-10 V / 4-20 mA. The O201 supports Modbus, CANbus protocols and a system fault relay. The module is designed with capability to add additional application logic for customer specific applications. 

The O201 is designed to collect data and easy to integrate into existing systems through serial communication like RS-485 or analog outputs like 0-10 V / 4-20 mA. The O201 supports Modbus, CANbus protocols and a system fault relay. The module is designed with capability to add additional application logic for customer specific applications. It is designed with the needs of Monitoring, Test platforms or Industrial Process monitoring integration needs. It has the data integration capability of multiple test platforms. Industry standard drivers availlable for a quick and easy connect to most popular laboratories softwares. 

  • Transformer
  • Gas Insulated Switchgear
  • MV Panel Switchgear
  • Air Insulated Switchgear
  • Rotating Machines

  • Sensors do not require any recalibration
  • No shift over time, high stability and repeatability
  • Robust packaging
  • Software designed for integration into test platforms
  • Robust datalogging and Analytics
  • Customizable according to customer specific applications
  • Suitable for OEM-type applications
Technical Specifications

Measurement Range

-80 °C to +300 °C (cryogenic 4 °K range optional)

Measurement range (Optional Range extensions)

Down to 4 °K / Up to +300 °C

Resolution

0.1°C

Accuracy

±1.0 °C (+/- 0.2 °C in relative temperature) 

Number of Channels

1 - 8 Channels

Logging

1 sec interval on USB / Micro SD card

Config port

USB (to use with Rugged connect windows software)

Max No of Channels

Expandable to 256 Channels, Daisy chain up to 32 units (with Modbus, Canbus) 

Comunication Ports

RS-485 (RS-232 optional converter) with Modbus , CANbus

Power

24 VDC

Memory

MicroSD external memory slot (up to 2 TB)

Analog output module

Fully configurable eight 0-10 V / 4-20 mA module(Optional)

Dimensions

4.72" x 6.34" x 1.89" 120 x 161 x 48 mm

Scan rate

200 ms / channel ( Optional: Faster scanning rates available)

Operating temp

-40 to 72 °C

Storage temp

-40 to 85 °C

Humidity

95% Non Condensing

Relay

System Fault relay (5A)

Get a Free Quote
GET A QUOTE
go top